4.5 Presetting and Deleting
Parameter Value Meaning Basic
8# #
basic setting
executes
This setting does not influence 1 and 2 (numbers stored in memory)
Parameter Value Meaning Basic
81
deletes all numbers in
group 1 (Day mode)
82
deletes all numbers in
group 2 (Night mode)
83
basic setting only
for parameters 3x
only 3..
84
basic setting only
for parameters 4x
only 4..
85
basic setting only
for parameters 5x
only 5..
The parameters 81 and 82 will execute deleting of all numbers stored in
memories for buttons.
The parameters 83 – 85 will execute a selective basic setting only for
parameters starting with 3.. – 5..
ATTENTION !!! the deleting is non-reversible !!!, It is then necessary to
program it again.