Alphatech Slim IPDP - 01 Guide de l'utilisateur

Naviguer en ligne ou télécharger Guide de l'utilisateur pour Interphones de porte Alphatech Slim IPDP - 01. Alphatech Slim IPDP - 01 User`s guide Manuel d'utilisatio

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 17
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 0
AREM 80 SmylTR
MREM 80 SmylTR
APS mini / APS mini Plus reader modules for IPDP Slim panels
User’s guide
®
© 2004 – 2012, TECH FASS s.r.o., Věštínská 1611/19, 153 00 Prague, Czech Republic, www.techfass.cz, techfass@techfass.cz
(Date of release: 01-03-2011, valid for FW version 5.08)
Vue de la page 0
1 2 3 4 5 6 ... 16 17

Résumé du contenu

Page 1 - MREM 80 SmylTR

AREM 80 SmylTR MREM 80 SmylTR APS mini / APS mini Plus reader modules for IPDP Slim panels User’s guide ® © 2004 – 2012, TECH FAS

Page 2 - 1 Content

Page 10 6.3 Alarm states The reader module can get in following alarm states: 1) Tamper alarm 2) Forced door alarm 3) Door ajar alarm 4) Antipas

Page 3 - 3 Technical parameters

Page 11 6.3.4 Antipassback alarm The Antipassback alarm is raised when an ID is read during the Time APB counter is running or when t

Page 4 - 3.3 Mechanical design

Page 12 6.6.1 Inserting cards into the reader’s memory Follow these steps for inserting cards into the reader module’s memory: Step 1 Step 2 Step

Page 5 - 4 Installation

Page 13 6.6.3 Deleting cards „above or below“ If a user loses his ID medium, it is usually impossible to delete the ID from the memory with the proc

Page 6 - Standard connection

Page 14 6.6.4 Deleting all cards from the reader’s memory Follow these steps for deleting all cards from the reader module’s memory: Step 1 Step 2

Page 7 - 4.5 D1 LED Indication

Page 15  Card 4 gets lost – Delete it using the card 2, which is available, and using the procedure from chapter 6.6.3 – Read

Page 8 - 5.1 Configurable parameters

Page 16  Time APB – user cannot repeatedly use his ID for defined time  Zone APB – user cannot repeatedly enter an area, where he is already pres

Page 9 - 6 Reader module functioning

Page 17 The disabling status changes and disabled actions are logged in the events archive. 7 Simplified access rights evaluation The model of ac

Page 10 - 6.3 Alarm states

All brand or product names are or may be trademarks of, and are used to identify products and services of, their respective owners. 1 Content 1 Con

Page 11 - 6.6 Programming mode

Page 3 2 Product Description The xREM 80 SmylTR 1) reader modules (125 kHz readers with an embedded single door controller) are designed for connect

Page 12

Page 4 3.2 Technical features Technical features Supply voltage 8 ÷ 28 VDC Current demand Typical 60 mA (12 V), 25 mA (28 V) Maximal 90 mA (8 V)

Page 13

Page 5 4 Installation 4.1 Reader module description Pic. 2: xREM 80 reader module, front (left) and rear (right) view Description Designation

Page 14

Page 6 4.3 Connecting the reader module with panel Standard connection Signal Connection + 8 ÷ + 28 VDC + contact (power supplier unit), re

Page 15 - 6.9 Antipassback function

Page 7 4.4 Standard connection Connection Input 1 Door contact, active when door closed Input 2 Request to exit button or handle contact, 0

Page 16 - 6.10 Disabling function

Page 8 4.7 Mounting and removal the xREM 80 SmylTR module The module is supplied with the IPDP SLIM panel, where it can occupy space of a single pus

Page 17 - 8 Useful links

Page 9 6 Reader module functioning The reader module supports the following functions:  Standard “Door Open” function.  Door status monitoring.

Commentaires sur ces manuels

Pas de commentaire