Page 6
4.3 Connecting the reader module with panel
Standard connection
Signal Connection
+ 8 ÷ + 28 VDC
+ contact (power supplier unit), red wire of C2 cable
(reader module), + contact (door lock)
0 V (GND)
- contact (power supplier unit), grey wire of C2 cable
(reader module), COM contact of relay 1 (entry panel)
Release lock from panel,
0 VDC active
NO contact of relay 1 (entry panel), orange wire of C1
cable (reader module)
Release lock from reader
Blue wire of C2 cable (reader module), - contact (door
lock)
Table 6: Standard reader module connection using the entry panel door lock release signal
This connection requires configuring the function of
the second input of the reader module as Request
to exit button (default module setting, see pic. 4).
The standard entry panel door lock release signal
is used as a signal for the reader module (orange
wire) to release the door lock then. The door lock
release is controlled by the output of the reader
module (open collector, 0 V (GND) active blue
wire).
The reader module is powered by a DC power supplier. When using suitable power
supplier and door lock type, you can power all components (entry panel, reader module
and door lock) from a single power supplier. If an AC powered door lock must be used, it is
necessary to use an individual external relay controlled by the OC signal from the reader
module to control the door lock.
Pic. 4: Reader module setting
Pic. 3:
Standard reader module connection with use
of
DC power supply
and the lock opening contact of the IPDP Slim entry panel